Impact of copper-clad aluminum conductor cables detailed
The nine-page IAN includes a section that provides information on the European, North American and international standards specifying twisted-pair cable. It then explains that all these cable specifications ""require the conductors to be of solid copper (whether or not they are stranded)."" In other words, twisted-pair cables with copper-clad aluminum or copper-clad steel conductors are, by definition, non-compliant with CENELEC, TIA and ISO/IEC standards.
The paper also gets into detail on the performance maladies that users will face if these cable types end up in their networks. It describes electrical-performance characteristics that suffer when copper-clad aluminum conductors are used. These characteristics include DC resistance, insertion loss/attenuation, return loss, near-end crosstalk and others. The paper also explains the negative effects of using this cable type in systems employing Power over Ethernet, the impact of flexing and bending a copper-clad aluminum cable, and the impact of oxidation.
In addressing the commercial implications of using copper-clad aluminum conductor cable, the FIA paper says, ""If a user specifies the use of CCA cables, then they cannot simultaneously demand Category-based performance for the cable or request that the installed cabling meets a given Class against ISO/IEC 11801 or EN 50173-1 without a significant risk of failure during acceptance testing."""